Securing Cylinders with Fire-Rated Walls Best Practices and Examples from OSHA

Recent posts

Mitigating Risks: The Vitality of Explosion-Proof & Non-Sparking Ventilation Fans in Confined Spaces

Mitigating Risks: The Vitality of Explosion-Proof & Non-Sparking Ventilation Fans in Confined Spaces Explosion-proof and non-sparking ventilation fans are specifically designed for use in hazardous environments where flammable substances are present. These fans are constructed using materials and components that are resistant to sparks and ignition sources. Here are the reasons why these fans are used in confined spaces: Spark Prevention Hazardous Environment Compatibility Compliance with Safety Standards Risk Mitigation For Downloading the File in PDF HD Format, please Click Below

Fire Extinguishing Agents: Transitioning to Safer Alternatives Post Carbon Tetrachloride and Chlorobromomethane Bans

Fire Extinguishing Agents: Transitioning to Safer Alternatives Post Carbon Tetrachloride and Chlorobromomethane Bans OSHA 1910.157(c)(3) : The employer shall not provide or make available in the workplace portable fire extinguishers using carbon tetrachloride or chlorobromomethane extinguishing agents. Carbon tetrachloride and chlorobromomethane were once used in fire extinguishers due to their fire suppression properties. However, their use has been significantly restricted and banned in many countries due to their harmful effects on human health and the environment. For Downloading the File in PDF HD Format, please Click Below

Accident Costs Direct & Indirect Costs with Examples and Differentiating Severity & Likelihood

Accident Costs Direct & Indirect Costs with Examples and Differentiating Severity & Likelihood What is direct & indirect cost? How to calculate the accident cost? What is the difference between Severity & Likelihood? What is the Importance of severity and likelihood in risk assessment? For Downloading the File in PDF HD Format, please Click Below

OHSPedia-RQ-2-Ensuring Safe Operations Hazard Management in Nitrogen Generation Plants and Ammonia Chillers

OHSPedia-RQ-2- Ensuring Safe Operations Hazard Management in Nitrogen Generation Plants and Ammonia Chillers A detailed and comprehensive risk assessment is essential to identify, evaluate, and mitigate hazards in a Nitrogen Generation Plant and Ammonia Chiller facility. This approach allows for the implementation of appropriate control measures, including the use of personal protective equipment, to safeguard the well-being of workers and prevent accidents and incidents. It's important to note that the hazards mentioned below are not a complete set, and each plant should conduct a customized risk assessment based on its unique operations, equipment, and processes. Regular reviews of the risk assessment should be conducted to ensure its continued effectiveness, especially when there are changes in operations or new hazards are identified. For Downloading the File in PDF HD Format, please Click Below

CAPA Safeguarding Construction Sites through Corrective and Preventive Measures

  CAPA Safeguarding Construction Sites through Corrective and Preventive Measures CAPA stands for Corrective and Preventive Action , which involves a systematic approach to address and mitigate risks, hazards, incidents, or non-compliances within a construction site. Examples of Corrective Actions in a Construction Examples of Preventive Actions in a Construction For Downloading the File in PDF HD Format, please Click Below

Ensuring Safety in Confined Spaces OSHA Regulations for Portable Lighting with GFCI

Ensuring Safety in Confined Spaces OSHA Regulations for Portable Lighting with GFCI According to OSHA 29 CFR 1926.405(a)(2)(ii)(G), the provision states: "Portable electric lighting used in wet and/or other conductive locations, such as drums, tanks, and vessels, shall be operated at 12 volts or less. However, 120-volt lights may be used if protected by a ground-fault circuit interrupter." Here's a tabular form explaining the requirements specified by OSHA 29 CFR 1926.405(a)(2)(ii)(G) for portable electric lighting in wet and conductive locations: Requirement Portable electric lighting used in wet and/or other conductive locations Shall be operated at 12 volts or less 120-volt lights may be used if protected by a ground-fault circuit interrupter (GFCI) For Downloading the File in PDF HD Format, please Click Below